CVE-2026-80711

medium Red Hat
CVSS v3 Base Score
5.5
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
EPSS Score
0.2%
Exploitation probability in 30 days
Top 95% most likely to be exploited
Attack Characteristics
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Confidentiality
None
Integrity
None
Availability
High
Published: August 28, 2026 (9 days ago)
Last Modified: August 28, 2026
Vendor: Red Hat
Source: REDHAT

Description

In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply. This happens on systems that use the fuel gauge without a charger supplier relationship in firmware. Return POWER_SUPPLY_STATUS_UNKNOWN when no supplier provides STATUS, and propagate other supplier lookup errors.

CWE

CWE-908

Affected Products

Red Hat Enterprise Linux 10Red Hat Enterprise Linux 6Red Hat Enterprise Linux 7Red Hat Enterprise Linux 8Red Hat Enterprise Linux 9

References